ELECTRICAL & ELECTRONICS |
|
Bottom |
|
ANA LOG ELECTRONIC
TRAINING KITS
 |
All Training Kits are supplied along with
necessary no. of patch cords (connecting leads) & instruction manual.
|
 |
Deluxe, Premium & Economy models are also
available of few training kits in which meters are provided. |
 |
Deluxe models are comprises of 72mm Acrylic
deluxe meters, whereas Premium models comprises of 3.5 digit LED digital
panel meters in lieu of round meters. |
 |
Incase of Deluxe and Premium Models,
complete instrument is housed in power coated rust proof steel cabinet
with tapered shape for better working angles. |
 |
Economy Models are with unregulated power
supply/ supplies in lieu of regulated power supply. |
|
|
|
|
|
CHARACTERISTICS OF
VACUUM TUBES (Valves)
VE-521 DIODE VALVE
CHARACTERISTICS APPARATUS WITH DC REGULATED POWER SUPPLY
Objective : VI
Characteristics of Diode valve at various filament voltages. Features
: Instruments comprises of DC regulated power supply 0-300V DC/30mA, AC
power supply 0-6.3V AC/1 Amp, two round meters for voltage & current
measurement, valve diagram is printed on Front panel, connections of
supplies & valve brought out at 4mm sockets. Standard Acc : Valve 6H6 |
|
|
|
|
VE-522 Triode Valve
Characteristic Apparatus with DC regulated power supply Objective : VI
Caharacteristics of Tride valve at various grid voltages Features :
Instrument comprises of DC regulated power supply 0-300V DC/30mA & 0-25V DC
10mA, AC power supply 6.3V AC/1 Amp, three round meters for voltage &
current measurement, valve diagram is printed on front panel, connections of
supplies & valve brought out at 4mm sockets. Standard Acc. : Valve 6C5/ 6J5 |
|
|
|
|
VE-523 Tetrode/Pentode
Valve Characteristics Apparatus
with DC Regulated Power
Supplies
Objective : Plate &
Screen characteristics of Tetrode & Pentode valve at various grid voltages.
Features : Instrument comprises of two DC regulated power suplies
0-300 V DC/30mA & one 0-25V DC/ 10mA, AC power supply 6.3V AC/ 1Amp, five
round meters for voltage & current measurment, valve diagram is printed on
front of front panel, connections of supplies & valve brought out at 4mm
sockets. Standard Acc. : Valve 6SJ7 |
|
|
|
|
EXPERIMENTS TO CALCULATE
e/m
VE-580 e/m Thomson
Method Objective : To study charge of an electron using thomson method.
Features : High voltage power supply (P 580) with one meter provided to
measure the deflection voltage. Complete with intensity, focus & deflection
controls. Standard Acc. : Compass box and set of strong Elico Magnets. Teak
wood stand with CRT mounted (W 580A ), Teak wood stand for compass box (W
580B) & teak wood U stand with scale on both the arms for placing magnets.
VE-581 e/m By Long
Solenoid/ Helical Method Objective : To study charge of an electron
using Helical Method Features : Kit comprises of high voltage power supply
unit with intensity focus X, Y deflection & solenoid current controls. Two
meters are provided in power supply for acceleration voltage control and for
solenoid current controls. One solenoid unit comprises of one solenoid
mounted on wooden stand & 3" CRT is kept in the solenoid pipe
V-582 e/m By Short
Solenoid Method Objective : To study of an electron using short solenoid
method. Features : Kit comprises of low voltage DC power supply unit witth
filament voltage and solenoid current controls. Two meters are provided for
anode voltage controls. One solenoid unit comprises of one solenoid mounted
on wooden stand & valve 41 is kept in the solenoid pipe. |
|
|
Top |
|
<< Back << |
>> NEXT >> |
|